Complete, Convertible, Innovative
Building on its success in the hip, knee and spine product areas, Medacta International is expanding into the shoulder arthroplasty market.
“With the Medacta Shoulder System, we are entering the fast growing upper extremity market with the same patient-centric vision and ambition that characterized our growth and success in knee, hip and spine technology: delivering innovation through high-level surgical education and providing real benefits to patients and healthcare system sustainability” said Alberto Siccardi, President and Founder of Medacta International.
Standard and Short versions
11 sizes for each version
Cementless (Ti-Plasma spray + HA) and cemented (only for Standard Stem) options
3 inclination options: 128 º /135 º /142º
Cementless (Ti-Plasma spray + HA) and cemented options
Suture Sleeves: Ø2.5mm
Adjustable head eccentricity (0 ÷ 5 mm)
10 sizes
Material: CoCrMo - ISO 5832-12 (ASTM F1537)
10 sizes
Material: Highly cross-linked polyethylene
Standard and Short versions
11 sizes for each version
Cementless (Ti-Plasma spray + HA) and cemented (only for Standard Stem) options
Two height options: +0 and +9 mm
Two version options: +/- 20º
Material: Ti6Al4V - ISO 5832-3 (ASTM F136)
Inlay design with HA
Suture Sleeves: Ø2 mm
Three height options: +0 / +3 / +6 mm
Inclination options: 145° and 155°
Material: Highly cross-linked polyethylene
Three diameter options: 22, 24.5 and 27 mm
Three peg length options: 15, 25 and 35 mm
Material: Ti6Al4V - ISO 5832-3 (ASTM F136) with HA (Grit blasted front surface)
Two diameter options: 24.5 and 27 mm
Three peg length options: 25, 30 and 35 mm
Material: Ti6Al4V - ISO 5832-3 (ASTM F136) + Type II anodization with 300μm Mectagrip
Four diameter options: 32, 36, 39 and 42 mm
Lateralized COR: 4mm
Embedded Inferior offset: 2mm
Material: CoCrMo - ISO 5832-12 (ASTM F1537)
10 sizes
± 15° of angulation
Material:
10 sizes
± 15° of angulation
Material: Ti6Al4V - ISO 5832-3 (ASTM F136) + Type II anodization
The humeral diaphysis has a self-centering and self-orienting shape. The calcar design has been optimize, through extensive trialing using 3D imaging and cadaver analysis, and delivers enhanced primary stability. Achieving a precise fit between stem and humeral canal is made possible with the extensive size range available with this system.
With an innovative design of the liner, the surgeon has the opportunity to adapt the system to the patient's conditions by potentially increasing joint ROM (145° humeral inclination) and maximizing joint stability (155° humeral inclination). The glenosphere has a lateral offset (4 mm) and also an inferior offset (2 mm) to reduce the risk of scapular notching. The complete hemispherical design delivers stability through full ROM.
The surgeon has the opportunity to ideally match and reproduce the head-stem offset using the double eccenter-head. This option delivers an adjustable head eccentricity between 0 and 5 mm. The Medacta Shoulder System provides 3 anatomical metaphysis inclination options (128° / 135° / 142°) to match the pre-operative humeral inclination.
In case of revision, the humeral diaphysis remains in place and is used to receive the reverse metaphysis and the reverse liner. This is a less invasive revision surgery option but continues to deliver satisfactory stability of the prosthesis.
MyShoulder is a patient-specific instrumentation, allowing the surgeon to realize his pre-operative 3D planning, based on CT images of the patient’s shoulder. The pre-operative 3D planning allows to manufacture an humeral resection guide and a glenoid positioning guide.
This innovative concept combines different features giving potential benefits to both the surgeon and to the patient.